Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

GDT:Position Composite FCF: Difference between revisions

From F4 Wiki
Created page with "{{Author Credit |author=Admin }} {{GDT Infobox |symbol=Position Composite FCF |type=Location |category=Composite FCF |standard=ASME Y14.5 |author=Admin |datums=Required; lower segments must be ordered subsets |modifiers=Material condition modifiers must be consistent across segments |tolerance_zone=Multiple segments with decreasing tolerance values |image=<!-- TODO: add diagram file name --> |mistakes=Using non-position/profile symbols; inv..."
 
No edit summary
 
Line 12: Line 12:
|modifiers=Material condition modifiers must be consistent across segments
|modifiers=Material condition modifiers must be consistent across segments
|tolerance_zone=Multiple segments with decreasing tolerance values
|tolerance_zone=Multiple segments with decreasing tolerance values
|image=<!-- TODO: add diagram file name -->
|image=GDT-Position-Composite-FCF.svg
|mistakes=Using non-position/profile symbols; invalid datum subsets; inconsistent modifiers; tolerance values not decreasing
|mistakes=Using non-position/profile symbols; invalid datum subsets; inconsistent modifiers; tolerance values not decreasing
|related=[[F4:Position Composite Validation]]
|related=[[F4:Position Composite Validation]]

Latest revision as of 19:30, 15 January 2026

Author: Admin

Position Composite FCF
Symbol Position Composite FCF
Type Location
Category Composite FCF
Standard ASME Y14.5
Author Admin
Datums Required; lower segments must be ordered subsets
Modifiers Material condition modifiers must be consistent across segments
Tolerance zone Multiple segments with decreasing tolerance values
Image GDT-Position-Composite-FCF.svg
Common mistakes Using non-position/profile symbols; invalid datum subsets; inconsistent modifiers; tolerance values not decreasing
Related F4:Position Composite Validation

Summary

Position composite feature control frames control a pattern with multiple tolerance zones in stacked segments.

Definition

A composite FCF contains two or more segments that refine location requirements. Lower segments are more restrictive and typically reference fewer datums.

When to use it

Use position composite FCFs to control a pattern with both overall location and finer pattern-to-pattern control.

Examples

Example: Composite position on a hole pattern
Two-segment composite position controlling overall and local pattern variation.

Common mistakes

  • Using non-position/profile symbols in composite segments.
  • Datum references not in ordered subset hierarchy.
  • Modifiers not consistent across segments.
  • Tolerance values that do not decrease in lower segments.

Related pages