Summary

F4 validates profile of a line against the ASME logic in the F4 Application and enforces application, datum, modifier, and pattern rules.

Validation rules

  • Profile of a line cannot be linked to a feature of size in F4.
  • Prohibited modifiers: diameter, LMC, MMC, projected tolerance zone.
  • True profile must be located using basic or toleranced dimensions.
  • Pattern application is allowed.
  • If the profile is applied to a datum surface, F4 flags ambiguity.
  • When basic dimensions are used, they must relate the true profile to the referenced datums.

Warnings and errors

F4 behavior

True profile not located


If the true profile is not located with basic or toleranced dimensions, F4 flags non-compliance.

F4 behavior

Ambiguous datum surface


If the profile is applied to a surface referenced as a datum feature, F4 flags ambiguity.

F4 behavior

Basic dimensions not related to datums


When basic dimensions are used, they must relate the true profile to the referenced datums.

F4 behavior

Prohibited modifiers


Diameter, LMC, MMC, and projected tolerance zone are not allowed on profile of a line.

F4 behavior

FOS linkage not allowed


Profile of a line must not be linked to a feature of size in F4.

Examples

  • Valid: profile of a line located by basic dimensions relative to datums.
  • Invalid: profile applied to a datum surface or missing true profile location.