Summary

F4 validates total runout against the ASME logic in the F4 Application and enforces datum, surface, modifier, and pattern rules.

Validation rules

  • A primary datum reference is required; tertiary datum references are not allowed.
  • Total runout is valid only for surfaces that surround or intersect the datum axis.
  • Total runout cannot be applied to a pattern.
  • FOS linkage is not allowed for total runout in F4.
  • Prohibited modifiers: diameter, LMC, MMC, projected tolerance zone, unequally disposed.
  • Tangent plane is only allowed when the surface intersects the datum axis.

Warnings and errors

F4 behavior

Missing datum


Total runout requires a primary datum reference; missing datums are rejected.

F4 behavior

Tertiary datum not allowed


Total runout cannot reference a tertiary datum.

F4 behavior

Invalid surface application


Runout must be applied to a surface that surrounds or intersects the datum axis.

F4 behavior

Pattern not allowed


Total runout applied to a pattern is rejected.

F4 behavior

FOS linkage not allowed


Total runout must not be linked to a feature of size in F4.

F4 behavior

Prohibited modifiers


Diameter, LMC, MMC, projected tolerance zone, and unequally disposed are not allowed on total runout.

Examples

  • Valid: total runout applied to a surface surrounding the datum axis with datum A.
  • Invalid: runout with a tertiary datum or pattern application.