F4:Perpendicularity Validation
More actions
Summary
F4 validates perpendicularity against the ASME logic in the F4 Application and enforces datum, feature-type, modifier, and pattern rules.
Validation rules
- A primary datum reference is required.
- Perpendicularity is valid only for a planar surface, a planar feature of size, or a cylindrical feature of size.
- Perpendicularity cannot be applied to a pattern.
- Unequally disposed is not allowed.
- Planar surface: diameter, LMC, MMC, and projected tolerance zone are not allowed.
- Planar FOS: diameter, projected tolerance zone, and tangent plane are not allowed.
- Cylindrical FOS: diameter is required; tangent plane is not allowed.
- If a linked size dimension exists, F4 compares the FCF tolerance to the size tolerance.
- If no size dimension is linked, F4 skips the size tolerance comparison.
Warnings and errors
F4 behavior
- Missing datum
Perpendicularity requires a primary datum reference; missing datums are rejected.
F4 behavior
- Invalid feature type
If the FCF is applied to anything other than a planar surface, planar FOS, or cylindrical FOS, F4 flags non-compliance.
F4 behavior
- Pattern not allowed
Perpendicularity applied to a pattern is rejected.
F4 behavior
- Not perpendicular to datum
If the toleranced feature is not perpendicular to the primary datum, F4 flags non-compliance.
F4 behavior
- Same feature as datum
If the toleranced feature is the same feature as the primary datum, F4 flags non-compliance.
F4 behavior
- Missing diameter
Cylindrical feature of size perpendicularity must include the diameter modifier.
F4 behavior
- Prohibited modifiers
Use the modifier rules for planar surfaces, planar FOS, and cylindrical FOS; prohibited modifiers are rejected.
Examples
- Valid: planar surface perpendicular to datum A.
- Valid: cylindrical feature of size perpendicular to datum A with the diameter modifier.
- Invalid: missing datum reference or missing diameter on cylindrical FOS.